Angela,In TRNBuild, you need to click on the "Outputs" button in the main project overview window then click the "Add" button in the window that pops up. Select the zones for which you want to see relative humidity (or other outputs) and then select RELHUM (NTYPE 8) from the list in the lower right hand side of the window and move it across to the list on the left. For a complete list of available NTypes, please refer to the Type56 documentation in the 06-MultizoneBuilding manual.
Kind regards, David At 18:53 5/3/2007, Angela Marcela Fandino Sepulveda wrote:
Dear Mr Bradley I am using TRNSYS - Type 56a and I am getting the following external files: " Bldg-Monthly.out, Bldg-HourlyTemp.out, Bldg-HourlyLoads.out " I would like also to obtain relative humidity hourly. I was wondering if I have to change the source code for Type56 or if I can obtain them in any other way. I really appreciate your kind assistance, Regards, Angela -- Angela Fandino Department of Civil and Environmental Engineering, The University of Melbourne, Australia Tel: +61 3 8344 4291, M: 0430 105 302 email: a.fandinosepulveda@pgrad.unimelb.edu.au URLs: http://www.civenv.unimelb.edu.au/autohome/webpage.php3?login=angelaf _______________________________________________ TRNSYS-users mailing list TRNSYS-users@engr.wisc.edu https://www.cae.wisc.edu/mailman/listinfo/trnsys-users
**************************************************************************************** Thermal Energy System Specialists (TESS), LLC David BRADLEY 2916 Marketplace Drive - Suite 104 Partner Madison, WI 53719 Phone: (608) 274-2577 USA Fax: (608) 278-1475 E-mail: bradley@tess-inc.com Web Pages: http://www.tess-inc.com and http://www.trnsys.com "Providing software solutions for today's energy engineering projects" ****************************************************************************************