Re: [TRNSYS-users] output files in parametric runs



Jose,
 Make sure that the names of your output files are the same as the name of your input file. If you are running MyInput.dck, then name all of your output files MyInput.out, MyInput.ou1, MyInput.ou2, MyInput.txt, etc. The extension doesn't matter at all, the output files will be text as always. You can also use a mode of Type25 in which results are appended on to the end of an existing data file instead of overwriting the data file. That option is controlled by one of the Type25 parameters.
Kind regards,
 David


At 05:00 5/3/2007, jose segis gonzalez garcia wrote:
Dear Trnsys-users:
 
I am trying to make parametric runs by TRNSED as per 7.9.2 chapter of the TRNSYS manual.
Despite the output file (by type25c) have the same name as the deck one, TRNEDIT doesn't append the run number to *.out files (*1.out, *2.out , *3.out... ) unless it writes over and over again the *.out in each simulation using the last parameters of the parametric table.
 
Anybody knows how get the *1.out, *2.out,.... *n.out files in parametric runs???
 
Cheers
 
Jose Segis Gonzalez
 
josegisgon@hotmail.com


Recibe ofertas de empleo adaptadas a tu perfil. Introduce tu CV en MSN Empleo.
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY                           2916 Marketplace Drive - Suite 104
Partner                                        Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com     and      http://www.trnsys.com

"Providing software solutions for today's energy engineering projects"
****************************************************************************************