Bertrand,
The parameter list for Type55 should be:
Integrate or
Sum:
1
Relative Starting Hour: 0
Duration:
8760
Cycle Repeat
Time:
8760
Reset
Time
8760
Absolute Starting Hour: 0
Absolute Stopping Hour: 8760
I think that will get you the annual mean value.
Cheers,
David