[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] type 109-user



Bertrand,
  Type109 can operate in two different modes. In one mode, it is set up to read a TMY2 format data file. In the other mode, it can be used to read data that does not correspond to the TMY2 format. Meteonorm data is in the TMY2 format so you do not want to use Type109 in its "user data" mode but in its "TMY2 format" mode. You will probably have to perform an Edit-Replace in your project and change from

Weather Data and Processing: User Format: Type109-User

to

Weather Data and Processing: Standard Format: TMY2: Type109-TMY2

Kind regards,
 David


At 07:38 3/19/2007, tchanche fankam bertrand wrote:
Dear all,
my type 109-user data file does not work properly.
i can not use meteonorm data.
please can anyone tell me how i can solve the proplem,
kind regards,


------------------------
TCHANCHE FANKAM Bertrand

C/O SUH Christopher
22 kadmeas-BOTANIKOS
Athens, GREECE
mobile:+30 69 42 95 59 52


Découvrez une nouvelle façon d'obtenir des réponses à toutes vos questions ! Profitez des connaissances, des opinions et des expériences des internautes sur Yahoo! Questions/Réponses.
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY                           2916 Marketplace Drive - Suite 104
Partner                                        Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com     and      http://www.trnsys.com