Gizmoog,
If you activate either an internal or an external shading device
(associated with a window) in TRNBuild, you can dynamically change the
R-value of the window during the simulation. There is no way to change
the basic thermal properties of a an opaque surface (wall, roof, or
floor) during a simulation as far as I know.
Kind regards,
David
At 03:07 2/26/2007, gizmoog wrote:
Dear users,
On multizone building (Type56), is there any possibility to change the
type of wall on a schedule to simulate night blinds for example ?
best regards,
Gizmoog