[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Using output of equations as a parameters



Mohammad,
Yes, you simply enter the name of the equation as the parameter value. If you are using the TRNSYS Studio you need to change the units of the parameter to "string" and then type the name of the equation. If you are using TRNEdit, it might look like:

EQUATIONS 1
MyValue = 13

...

UNIT 5 TYPE 718
PARAMETERS 1
MyValue ...

Bear in mind, though that PARAMETER values are read once at the beginning of a simulation and are not updated during the simulation. Thus the result of your equation may change throughout the simulation but the component parameter value will not be updated.

Kind regards,
 David


At 09:17 1/8/2007, mohammad abdunnabi wrote:
Dear Trnsys users

Is it possible to use the output of equations (the output is calculated from other output compoenets) as a parameters (not input) in other component in Trnedit. If not, is any way that I can do to use the output of any compenent as a parameter to other components in Trnedit simulation program.

many thinks in advance

M. Abdunnabi

__________________________________________________
Do You Yahoo!?
Tired of spam?  Yahoo! Mail has the best spam protection around
http://mail.yahoo.com

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY                           2916 Marketplace Drive - Suite 104
Partner                                        Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com     and      http://www.trnsys.com