[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TRNSYS-users] Doubt with Type 534 (Tess Library)
Dear Silvia,
The external file that is read by Type534 is usually created by the
Simulation Studio plugin associated with the Type534 proforma. To launch
the plugin, drag Type534 onto your assembly panel, double click it to open
it and then click on the little magic wand icon / button in the lower left
hand corner of the window. The plugin should launch at that point - if you
don't see it, look along the taskbar at the bottom of the screen. You then
specify a file name for the external file (it may be named anything you
want) and make your settings in the plugin window. Once you have finished,
the plugin will write the correct file for you.
Kind regards,
David
At 08:59 12/19/2006, Soutullo Castro Silvia wrote:
Dear all,
We are working in Type 534 ( Cylindrical Storage Tank with Immersed Heat
Exchangers) from Tess library and we dont know how to fill in the file
that requires the folder "External File".
We have tested the example of Tess Library (Example_534.dat) but we dont
understand that there is to put in the file *.dat
Could somebody help us?
Thanks in advance,
Silvia Soutullo castro
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users
****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY 2916 Marketplace Drive - Suite 104
Partner Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages: http://www.tess-inc.com and http://www.trnsys.com
"Providing software solutions for today's energy engineering projects"
****************************************************************************************