[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[TRNSYS-users] WINDOW problem
dear trnsys users ,
using TYPE 56, we have some problems with the U value of the window. For
exemple I use this window from the german library (window type, library
...) :
Unit System : SI
Name : TRNSYS 15 WINDOW
LIB
Desc : Waermeschutzglas,Ar, 1.3
71/59
Window ID : 2002
Tilt : 90.0
Glazings : 2
Frame :
11
2.270
Spacer : 1
Class1
2.330 -0.010 0.138
Total Height: 1219.2 mm
Total Width : 914.4 mm
Glass Height: 1079.5 mm
Glass Width : 774.7 mm
In the *.bui file , I consider an area of 4.15m² . Which value of U (and
of area) is really used in the simulation ? I have compared with the
steady state and I cannot find 1.3 W/m²K , nor 0.85*1.3 + 0.15*8.17/3.6
(If I consider the frame).
best regards
G. Fraisse
°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°
LOCIE - groupe DENED (Développement Énergétique Durable)
Polytech'Savoie - Université de Savoie
Campus Scientifique Savoie Technolac
73376 - Le Bourget du Lac Cedex (France)
Tel. +33 (0)4.79.75.88.95 (Fax : 81.44)
°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°