[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] labels missing in type 65



Dear Constanze,

My guess is that you are using more than 5 online plotters-printers in your simulation. If that is the case, please look at the list file, and you will see an error that tells you that 'Only 5 online plots may be active during a simulation'. Only the first 5 online plotters are producing the plots and printing the files with the right header. The other online plotters are printing at time steps different than the initialization time step.

My suggestion is that you replace the Type65 of those online plotters that are not resulting in a plot window with a Type25 (printer).

We will fix this problem in the next release: if more than 5 online plotters-printers are present in the simulation, write the output files although no plot is shown during the simulation.
Best regards,

Diego


Constanze.Bongs@csiro.au wrote:
Hi,
// /I am having the following problem with type 65. I am letting Trnsys print simulation results to a file assigned in type 65. However, it prints the results but not the labels into the file. The strange thing is that this only happens for two of 10 type 65 components in my simulation. I used the type causing problems in a separate deck before and it printed the labels then. I haven't really changed anything and could not figure out where the problem is coming from. I also copied another type65 which works alright and configured it in the same way as the file causing problems. The same problem occurred. Type 65 is supposed to print the results (and labels) of an embedded excel calculation sheet and I assigned it to print eight different values. /
/Has anybody ever encountered a similar problem and knows how to fix it?/
// /Cheers,/ // /Constanze/
------------------------------------------------------------------------

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users


--

Diego A. Arias
TRNSYS Coordinator
Solar Energy Laboratory
University of Wisconsin - Madison
1500 Engineering Drive
Madison, WI 53706