Dear candy
I have not had this error before, but the manual says this: “ERROR 185
- The TYPE 56 multi-zone building model has reported a singular
matrix. The star matrix is singular. Check the input file description
for inconsistencies in the building description.”. So there might be
something wrong in your .bui file. I don’t know if this gives you any
clue.
Concerning front and back: back is the side facing the zone
Good luck
Stefan
------------------------------------------------------------------------
*Van:* trnsys-users-bounces@engr.wisc.edu
[mailto:trnsys-users-bounces@engr.wisc.edu] *Namens *candyhe
*Verzonden:* maandag 3 juli 2006 16:35
*Aan:* trnsys-users@engr.wisc.edu
*Onderwerp:* [TRNSYS-users] Star matrix error of TYPE56
Dear all,
Does any body know what will cause such an error? I uesd the Prebid to
model a 6 zones building. When I run it in TRNSYS, I got the error report.
***** ERROR ***** TRNSYS ERROR # 185
UNIT 4 TYPE 56 MULTIZONE BUILDING
STAR MATRIX IS SINGULAR - SIMULATION STOPPED.
BTW, I am also a little bit confuse about the adjacent wall. Which
direction is the front? and which direction is the back? Would any one
help me out? Thanks very much.
Best Regards,
Candy,He Miaomiao
MPhil. Student
Department of Mechanical Engineering
University of Hong Kong
http://www.hku.hk/
(+852)28592642
------------------------------------------------------------------------
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users