João,
Regarding your first email, it is not too uncommon to have a few non-converged time steps within a simulation. If you have a lot of nonconverged time steps, then there is of course cause for concern.

Forrtl: error(63): output conversion error, unit 6, file c:\test\v7.lst

1. What´s the meaning of this error ?

that error means that there was a problem writing to the list file for some reason. One common cause is that a model might be trying to write to the list file after the list file has been closed. In the error message, you can sometimes determine which routine caused the error. If not, then you should contact your distributor so that they can debug the simulation for you.
Kind regards,
 David


****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY                           2916 Marketplace Drive - Suite 104
Partner                                        Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com     and      http://www.trnsys.com

"Providing software solutions for today's energy engineering projects"
****************************************************************************************