[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Changes in Proforma



Rémi,
The Studio proforma file is a user friendly presentation of information contained in the component's source code. In order to change a variable from a parameter to an input, you need to modify and recompile the component's Fortran source code using a Fortran Compiler (Compaq Visual Fortran 6.6b or Intel Visual Fortran are highly recommended).
Kind regards,
  David

At 08:03 AM 6/1/2005, Charron, Rémi wrote:
Hello,

I am currently running a simulation where I want to change variables from
Parameters to Inputs.  When I change the Proforma, and replace the
component, my simulation stops working.  When I try to run the file, I get a
couple of error messages.  The first is that there is a Range Check Error,
and the second is that there is an Unexpected Error.

Is there something else I need to do when I change the definition of
Variables?

Thanks.

Rémi

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY                           2916 Marketplace Drive - Suite 104
Partner                                        Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com     and      http://www.trnsys.com

"Providing software solutions for today's energy engineering projects"
****************************************************************************************