[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] reading EP weather data



Dear trnsys users,

I'm using type 89 mode -3 to read EnergyPlus weather data (an epw file).
Time step is 1h.
It seems that type 89 shifts and interpolates all data (except solar radiation data), as in the example
you can read below. Is it correct? What does it mean?
Thank you for helping.
Best regards

Adriana

type 89 output
TIME       Month       DryBulb                 
0124.00
112.60
211.00
310.45
41-0.35
51-0.85
61-0.80
71-0.45
81-0.05
910.25
1010.60
1111.30
1212.40

EnergyPlus source file:
dayhourminute dry bulb
1160 1.2
1260 0.8
1360 0.1
1460 -0.8
1560 -0.9
1660 -0.7
1760 -0.2
1860 0.1
1960 0.4
11060 0.8
11160 1.8
11260 3
11360 4.6

------------------------------------------------------------
Adriana Angelotti, PhD
Politecnico di Milano
Dipartimento Best
v. Bonardi 3
20133 Milano
Italy
Tel/Fax + 39 02 2399 5118