[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] error 14 procedure for Trnsys16



Dear Geoffrey,
  The values that were previously contained in the param.inc file are now
contained in one of the kernel data modules called "TrnsysConstants.f90" To
change the allowable number of equations in your input file, you need to change
the value of "nMaxEquations" in TrnsysConstants and the recompile the TRNDll.dll
file. If you use the Compaq Visual Fortran compiler, a workspace is provided in
the \Compilers\ directory.
Kind regards,
  David

Quoting Geoffrey van Moeseke <vanmoeseke@arch.ucl.ac.be>:

> Hello
>
> Trnsys 15 error.hlp file describe in the "error 14" section a procedure to
> modify allowed number of  equations. Has this procedure change under the
> new Trnsys 16 version? It seems that notified directories are no longer the
> same. Is there other changes?
>
> Thanks a lot
>
>
> ----------
> Geoffrey van Moeseke, Ir. Architecte
>
> Architecture et Climat, Université Catholique de Louvain
> Place du Levant 1,                                              phone : +
> 32 10 47 21 38
> 1348 Louvain-La-Neuve, Belgium                          fax : + 32 10 47 21
> 50


-- 
David BRADLEY
Thermal Energy System Specialists, LLC
2916 Marketplace Drive - suite 104
Madison, WI  53719
ph: +1 608 274 2577
fax: +1 608 278 1475
email: bradley@tess-inc.com