Edward,
I want to use Type 28 a (Include Energy Balance) so that I can save the
results to an external file. However, everytime I change Operation code
1 from default value of 0 (zero) to a positive value, it does not change
! The same thing happens when I change other operation codes from 0
(zero) to a positive value !!! No problem when I used 28c, but the
results are in the listing file.
I could not reproduce your problem with the latest TRNSYS 15 release
(15.3.00 + patch on the SEL website).
It looks like the minimum/maximum values for that parameter are wrong in
the proforma. If this is the problem a workaround is to set the variable
type to string. This will allow you to type in any value.