[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TRNSYS-users] PV with PCM
BOUZOUKAS ASTERIOS wrote:
As I was searching internet for a TRNSYS type for PCM in the back
side of a PV I found this web site
http://sel.me.wisc.edu/trnsys/downloads/trnsedapps/demos/pvh-array.htm
Do you know if this kind of type exists or the theory that cover
this kind of type. Thank you very much.
Unfortunately, I was not able to locate the source code of that Type. It
seems to be an early variant of what is now Type 180 (in HYDROGEMS,
which is now part of the standard library in TRNSYS 16) where the
equation for Tc, the cell temperature, is modified to take PCM's into
account.
The equation for Tc can be easily identified in Type 180, so I assume it
would be possible to take PCM's in consideration without too much effort
by modifying that equation. Or may be someone on this list still has a
copy of that component with the PCM's in it, in which case I would be
pleased to add it to the TRNLIB section...
Kind regards,
Michaël Kummert
--
_________________________________________________________
Michaël Kummert
Solar Energy Laboratory - University of Wisconsin-Madison
1303 Engr Res Bldg, 1500 Engineering Drive
Madison, WI 53706
Tel: +1 (608) 263-1589
Fax: +1 (608) 262-8464
E-mail: kummert@engr.wisc.edu
SEL Web Site: http://sel.me.wisc.edu
TRNSYS Web Site: http://sel.me.wisc.edu/trnsys